Abstract

The cross recurrence plot (CRP) method was applied on the simultaneous current and voltage fluctuation time records in consideration of their possible nonlinear kinetics. Sequential cross recurrence quantification analysis (CRQA), CRP pattern recognition and synchronization analysis were used to screen the paralleled running from the uncorrelated oscillations, to recognize the impedance component, and to identify the synchronization type and degree in the dynamical view point. With the aid of the proposed approach, the sulfur-induced localized corrosion of the alloy 718 in the high temperature brine was detected and evaluated during the evolutive corrosion process.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call