Abstract

Gait pattern alterations were previously reported in association with objective patellar instability (OPI). Gait pattern comparison between a series of patients having undergone medial patellofemoral ligament (MPFL) reconstruction and a sample of control subjects. Thirty patients at 6 months postoperatively after MPFL reconstruction and thirty control subjects were enrolled in the study for a clinical and biomechanical assessment including gait analysis at three selected walking rates using the GAITRite(®) system. The mean raw IKDC score was 73 (± 19), and the mean Kujala knee function was 84 (± 17.5). The study of gait did not demonstrate any significant difference between the two groups at a normal and fast walking rate. At a 10 km/h running speed, the single-support phase was significantly shortened by a mean 2.33% (p < 0.05), the swing phase by a mean 2.64% (p < 0.05) and the double-support phase by a mean 3.49% (p < 0.05) on the operated side. MPFL reconstruction reported good midterm functional and clinical results in the management of OPI. At 6 months postoperatively, the patient gait pattern was similar to that observed in healthy subjects at a normal and fast walking speed. However, our study revealed persistent gait abnormalities at a 10 km/h running speed. These gait alterations seemed to be related to the ligament reconstruction in itself due to the higher strain applied on the reconstructed MPFL during running cycle (10 km/h). Level of evidence IV.