Abstract
Spent coagulant in water supply plant sludge was extracted with H2SO4 and the efficiency of the reused coagulant was studied. The optimum pH values for coagulant extraction and clarification with the reused coagulant were 3.0–4.0 and about 6, respectively. In treating raw influent obtained from a sewage treatment plant and wastewater from a coastal landfill site, the removal of chemical oxygen demand (COD), total nitrogen, and total phosphorous with the recovered coagulant was higher than that with commercial aluminum sulfate or polyaluminum chloride. In addition, the sludge settling properties, the extra sludge mass formation, the supernatant quality, and the cost of reagents were also studied. The coagulant recovered from water supply plant sludge by H2SO4 extraction could be successfully reused for the clarification of domestic and food industry wastewaters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.