Abstract
The present study aimed to evaluate the feasibility and safety of the novel left bundle branch pacing (LBBP) procedure that uses isoelectric interval as an endpoint for lead implantation. A total of 41 patients with indications for pacing were enrolled. All patients underwent a novel LBBP procedure guided by recording an isoelectric interval as an endpoint for lead implantation. The procedural details and electrophysiological characteristics were then analyzed. A total of 38/41 (92.7%) cases were confirmed of left bundle branch (LBB) capture. An isoelectric interval was observed in 36/41 cases (87.8%). A total of 36/41 (87.8%) cases with LBB potential were observed. The mean unipolar LBBP threshold at the implant was 0.5 ± 0.2 V. The mean sensed amplitude of the R wave and the pacing impedance at the implant were 12.9 ± 5.0 mV and 723.5 ± 117.1 Ω. During the final threshold testing, a transition from non-selective to selective LBBP (S-LBBP) was demonstrated in 26 patients. A transition from non-selective LBBP (NS-LBBP) to left ventricular septal myocardial capture was observed in 12 patients. Using an isoelectric interval as an endpoint to guide the LBBP was feasible in a high proportion of captured LBB cases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.