Abstract

Abstract. Ozone data derived from the Tropospheric Monitoring Instrument (TROPOMI) sensor on board the Sentinel-5 Precursor satellite show exceptionally low total ozone columns in the polar region of the Northern Hemisphere (Arctic) in spring 2020. Minimum total ozone column values around or below 220 Dobson units (DU) were seen over the Arctic for 5 weeks in March and early April 2020. Usually the persistence of such low total ozone column values in spring is only observed in the polar Southern Hemisphere (Antarctic) and not over the Arctic. These record low total ozone columns were caused by a particularly strong polar vortex in the stratosphere with a persistent cold stratosphere at higher latitudes, a prerequisite for ozone depletion through heterogeneous chemistry. Based on the ERA5, which is the fifth generation of the European Centre for Medium-Range Weather Forecasts (ECMWF) atmospheric reanalysis, the Northern Hemisphere winter 2019/2020 (from December to March) showed minimum polar cap temperatures consistently below 195 K around 20 km altitude, which enabled enhanced formation of polar stratospheric clouds. The special situation in spring 2020 is compared and discussed in context with two other Northern Hemisphere spring seasons, namely those in 1997 and 2011, which also displayed relatively low total ozone column values. However, during these years, total ozone columns below 220 DU over several consecutive days were not observed in spring. The similarities and differences of the atmospheric conditions of these three events and possible explanations for the observed features are presented and discussed. It becomes apparent that the monthly mean of the minimum total ozone column value for March 2020 (221 DU) was clearly below the respective values found in March 1997 (267 DU) and 2011 (252 DU), which highlights the special evolution of the polar stratospheric ozone layer in the Northern Hemisphere in spring 2020. A comparison with a typical ozone hole over the Antarctic (e.g., in 2016) indicates that although the Arctic spring 2020 situation is remarkable, with total ozone column values around or below 220 DU observed over a considerable area (up to 0.9 million km2), the Antarctic ozone hole shows total ozone columns typically below 150 DU over a much larger area (of the order of 20 million km2). Furthermore, total ozone columns below 220 DU are typically observed over the Antarctic for about 4 months.

Highlights

  • Today’s operating satellite instruments produce a reliable picture of the Earth’s atmosphere and its chemical composition

  • Ozone data from July 2019 to April 2020 from the Tropospheric Monitoring Instrument (TROPOMI) sensor on board the EU/ESA Copernicus Sentinel-5 Precursor satellite are scientifically used for the first time in combination with the long-term ozone data set from the European satellite data record GOME-type Total Ozone Essential Climate Variable (GTO-ECV) from July 1995 to June 2019 (Coldewey-Egbers et al, 2015)

  • This study presents a description of the Northern Hemisphere (NH) winter and spring season 2019/2020 and considers the dynamical situation of the stratosphere and the evolution of the ozone layer in the Arctic region

Read more

Summary

Introduction

Today’s operating satellite instruments produce a reliable picture of the Earth’s atmosphere and its chemical composition. As shown, in March and early April 2020, very low TOC values were measured in the Arctic, the stratospheric chlorine content in 2020 was known to be lower than in previous years We compare winter 2019/2020 to winters with similar dynamical conditions in Arctic spring but which did not show TOC values below 220 DU over the polar NH in spring over an extended time period. We demonstrate that the low TOC values over the Arctic observed in spring 2020 are far from the conditions usually observed in the Antarctic ozone hole. 4 it is compared with two NH winter and spring seasons, namely 1996/1997 and 2010/2011, where similar polar stratospheric conditions – including low TOC values – have been observed.

Meteorological data
Ozone data
Findings
Discussion
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.