Abstract

SummaryThe serious fire incident at Grenfell Tower in London, involving a combustible façade system that was installed as part of a major refurbishment of the building, has raised concerns regarding the fire risk that these systems pose. The fire spread over the façade of the Tower was previously numerically modelled and this model was validated by comparison with observational data. This model was used to determine the fire behavior of the façade and the fire's propagation into apartments through windows. In the present paper, impact models are used to evaluate tenability conditions inside the Tower, especially for the apartments in the first corner of the Tower that caught fire. The source of toxic effluents includes the components used in the refurbishment of the façade and the apartment furniture. Different hypotheses of gas yields are tested to assess variability and unknowns in the burning conditions. An extensive literature review was conducted to investigate the toxic yields to be considered in the simulations. Tenability conditions are assessed for each apartment during the fire spread over the façade. This leads to the quantification of the thermal and toxic environment inside the apartments. Two different models are tested for thermal and toxic threats, and the influence of the insulation material used in the façade is investigated. The results showed that the same conclusion can be made regardless of the input data for toxicity and the model used, within the limits of the studied dataset and conditions. Fires from the apartments quickly drive tenability conditions, independently of the dataset and model used, and even if mineral wool is used instead of poly‐isocyanurate as façade insulant.

Highlights

  • The Grenfell Tower is a 24-storey high-rise building located in London

  • The performance of the façade system installed on the Grenfell Tower was simulated using a model that was validated at intermediate and large scales, as addressed in references 7,8.The simulations closely matched the experimental results of reference 9 and confirmed that the aluminum composite material (ACM) cladding was the main element driving the global fire behaviour of the tested façade systems

  • An impact model that includes fire loads and fire propagation in the apartments was used to assess tenability conditions inside the Tower. This analysis was conducted in accordance with ISO 13571, and using an alternative model adapted to pass/fail analysis

Read more

Summary

Summary

The serious fire incident at Grenfell Tower in London, involving a combustible façade system that was installed as part of a major refurbishment of the building, has raised concerns regarding the fire risk that these systems pose. The fire spread over the façade of the Tower was previously numerically modelled and this model was validated by comparison with observational data. This model was used to determine the fire behavior of the façade and the fire’s propagation into apartments through windows. Tenability conditions are assessed for each apartment during the fire spread over the façade. This leads to the quantification of the thermal and toxic environment inside the apartments. Two different models are tested for thermal and toxic threats, and the influence of the insulation material used in the façade is investigated. KEYWORDS CFD, façade insulation, fire propagation, impact model, ISO 13571, numerical simulation, toxicity, ventilated façade

| INTRODUCTION
Findings
| CONCLUSIONS
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call