Abstract

Here we report the method of anastomosis based on double stapling technique (hereinafter, DST) using a trans-oral anvil delivery system (EEATM OrVilTM) for reconstructing the esophagus and lifted jejunum following laparoscopic total gastrectomy or proximal gastric resection.As a basic technique, laparoscopic total gastrectomy employed Roux-en-Y reconstruction, laparoscopic proximal gastrectomy employed double tract reconstruction, and end-to-side anastomosis was used for the cut-off stump of the esophagus and lifted jejunum.We used EEATM OrVilTM as a device that permitted mechanical purse-string suture similarly to conventional EEA, and endo-Surgitie.After the gastric lymph node dissection, the esophagus was cut off using an automated stapler. EEATM OrVilTM was orally and slowly inserted from the valve tip, and a small hole was created at the tip of the obliquely cut-off stump with scissors to let the valve tip pass through. Yarn was cut to disconnect the anvil from a tube and the anvil head was retained in the esophagus.The end-Surgitie was inserted at the right subcostal margin, and after the looped-shaped thread was wrapped around the esophageal stump opening, assisting Maryland forceps inserted at the left subcostal and left abdomen were used to grasp the left and right esophageal stump. The surgeon inserted anvil grasping forceps into the right abdomen, and after grasping the esophagus with the forceps, tightened the end Surgitie, thereby completing the purse-string suture on the esophageal stump.The main unit of the automated stapler was inserted from the cut-off stump of the lifted jejunum, and a trocar was made to pass through. To prevent dropout of the small intestines from the automated stapler, the automated stapler and the lifted jejunum were fastened with silk thread, the abdomen was again inflated, and the lifted jejunum was led into the abdominal cavity.When it was confirmed that the automated stapler and center rod were made completely linear, the anvil and the main unit were connected with each other and firing was carried out. Then, DST-based anastomosis was completed with no dog-ear.The method may facilitate safe laparoscopic anastomosis between the esophagus and reconstructed intestine. This is also considered to serve as a useful anastomosis technique for upper levels of the esophagus in laparotomy.

Highlights

  • It has reported that safe and easy way of conducting anastomosis between the esophagus and digestive tract following total or proximal gastrectomy by the hemi-double stapling technique using EEATM OrVilTM1 [1]

  • We have been reported on the use of the EEATM OrVilTM stapler in end-to-side anastomosis for esophagojejunostomy with the hemi-double stapling procedure, there was some minor leakage experienced during the 35th case, we sought to improve this technique [2]

  • Reconstruction during the low anterior resection is generally performed with the double stapling technique, with ruptured sutures being reported in 2.6-17% of cases [3,4,5,6]

Read more

Summary

Background

It has reported that safe and easy way of conducting anastomosis between the esophagus and digestive tract following total or proximal gastrectomy by the hemi-double stapling technique using EEATM OrVilTM1 [1]. In this technique there was always a dog ear, and even though we were able to maintain blood flow, we were unable to resolve the weak point. Posture In general cases, for the basic operation, the patient was kept in a spine position with his/her legs opened. An operator stood on the right-hand side and a primary assistant stood on the left-hand side of the patient

Methods
Findings
Discussion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.