Abstract

A non-contact testing method is proposed for encapsulation treated or insulation coated switching power supplies, which is implemented by reconstructing the pulse width modulation (PWM) signal of switching converters from the near field radiation of magnetic components. The radiation pattern of a buck converter is investigated, and the magnetic field sensing probe and PWM signal reconstruction circuit are also illustrated. The reconstruction testing is carried out on a buck converter; the duty cycle error of the reconstructed PWM signal is less than 0.2%, which validates the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.