Abstract

Preliminary field measurements of soil‐gas radon (Rn) concentrations can provide an initial assessment of the Rn potential in any location and aid in designing a larger or more detailed sampling program. Radon reconnaissance requires some special considerations because a large area must be covered in a short period of time and analyses must be made soon after collection because of Rn decay. A simple approach to collection and field analysis consists of a small‐diameter probe pounded into the ground to a depth of at least 0.75 m. Analysis is by an alpha‐scintillometer. Soil‐gas samples collected along a traverse in Prince Georges County, Maryland, demonstrate the utility of the technique. Although this region in the Coastal Plain province might be considered to possess the type of geologic setting that would not contribute to significant Rn potential, the reconnaissance sampling revealed Rn soil‐gas concentrations of up to 2500 pCi/L (picocuries per liter) indicating that the potential exists for indoor accumulations in excess of 4 pCi/L.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.