A method to determine the photovoltaic (PV) series–parallel array configuration that provides the highest Global Maximum Power Point (GMPP) is proposed in this paper. Such a procedure was designed to only require measurements of voltage and current of each string, which avoids to perform experiments in each module. The ideal single-diode model parameters of each module in the string are obtained from the analysis of the voltage vs. current characteristics of the string. Using the estimated parameters, all feasible PV array configurations are evaluated to determine the array configuration that provides the highest GMPP. Finally, the proposed solution is validated using simulations and experimental data.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.