Abstract
Prosthetic cardiac thrombosis is a life-threatening complication that needs prompt diagnosis and therapy. We used recombinant tissue-type plasminogen activator (rT-PA), followed by heparin, in three patients with mitral prosthetic thrombosis, which was evident in two and suspect in one. Transthoracic and transesophageal echocardiography were employed in the diagnosis of both thrombosis and its resolution. No complications occurred. Immediately after the end of treatment with rT-PA, clinical status and echocardiographic data improved in all cases: transthoracic echocardiography showed the normalization of prosthetic function and transesophageal echocardiography showed resolution of thrombosis. One patient needed reoperation for rethrombosis due to the presence of prosthetic fibrous clot. rT-PA, followed by heparin, led to a good clinical result without bleeding and embolic complications in selected patients with mitral prosthetic thrombosis. Transthoracic and transesophageal echocardiography are complementary diagnostic tools in the diagnosis and management of patients with prosthetic thrombosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.