Abstract

Recent advances in research on soft X‐ray lasers at Princeton are described. A one‐dimensional code has been constructed which is in good agreement with the measured radial dependence of soft X‐ray gain at 182 A in a magnetically confined recombining plasma. Multichannel detectors have been installed in the diagnostic spectrometers and spectra of the line emission in axial and transverse directions are presented. Initial measurements of the relative divergence and, very recently, absolute divergence measurements of the axial 182 A beam have been made by scanning the axial spectrometer across the beam. The absolute divergence was measured to be in the range 5–10 mrad, depending on experimental conditions and the maximum power of soft X‐ray beam was ∼100 kW. finally, a new two laser approach to create gain at wavelengths below 100 A is briefly described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.