Abstract

ABSTRACTA KrF excimer laser exposure method has been developed for laboratory use, which employs 10 to 1 achromatic projection lens of 0.37 NA and 5x5 mm field size , and a TTL alignment system using the double diffraction method, which was realized by the use,of the achromatic lens. Novolak type mid-UV resists, such as AZ-5214 and PR-1024, were best suited for use in 248 nm exposure, considering the sensitivity and etching resistance from a practical viewpoint, and an additional post exposure baking process also improved the resist profile. The dependences of the exposure characteristics on the energy density per pulse and pulse frequency of these resists were not observed in the region of the practical exposure conditions. An alignment precision of x±30-= 0.2 μm was achieved for the alignment mark consisting of poly Si pattern. Thus, a 0.3 μm line and space pattern was realized by using tri-level resist process and a 0.2 μm gate pattern was successfully fabricated on the coplanar pattern with a 0.4 μm step.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.