Abstract

Abstract In this paper, the most recent advances in the time-domain reflectometry (TDR)-based system for leak-localization in underground pipes are described in detail. More specifically, a new design of sensing element and the use of a new connection modality are proposed. Thanks to these new features, the practical implementation of the system becomes much quicker and its use more effective. Additionally, the present work also describes all the practical aspects and technical details (from installation to functional tests), related to the practical implementation of the system. Finally, to assess the possibility of further increasing the cost-effectiveness of the TDR-based leak localization system, experimental tests were carried out by comparatively using two TDR instruments, differing in specifications and costs, to identify the position of a leak.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.