Abstract
Destructive characterization of recast layer on reverse micro EDM-ed (RMEDM) surface renders the component unusable for its intended application. X-ray micro computed tomography (µCT) is a non-destructive technique widely used for characterization of internal structures of different materials. Array of hemispherical shaped micro features fabricated by RMEDM by employing taper ended blind holes led to variation in recast layer thickness of the micro features both along its length and position on the surface of workpiece. µCT characterization of recast layer thickness revealed that with respect to location on micro feature, the tip of micro feature had the highest recast layer thickness and the base the lowest. Also, with respect to location of micro feature on the surface of workpiece, the micro feature at the periphery had the lowest recast layer thickness whereas the micro feature at the centre had the highest.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.