Abstract
Oscillating droplets rebounding completely from non-superhydrophobic surfaces (polydimethylsiloxane, PDMS) were experimentally studied and theoretically interpreted. The new experimental finding is that, with increasing the droplet impact Weber numbers (We), the recovery coefficient of droplet velocity, which is defined as the ratio of the rebounding velocity over the impact velocity, has an overall trend of decrease but in a fluctuating manner. Physically, a sufficiently large droplet freely falling under gravity has an inevitable oscillation, which makes the impacting droplet shape slightly deviate from being spherical and in turn affects the interaction between the droplet and the surface. The fluctuating recovery coefficient is the result of the periodically varying phase of droplet oscillation with increasing We, and increasing the droplet viscosity can suppress the droplet oscillation and then the fluctuation amplitude of the recovery coefficient. A theoretical model of oscillating droplet rebound is proposed and well fits the present experiments over a wide range of We.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.