Abstract

The systematic review presented herein was performed to descriptively analyze the causes for the failure of computer-aided design/computer-aided manufacture (CAD/CAM) restorations. The meta-analysis reported herein was performed to estimate long-term survival and success rates of CAD-CAM fabrications. Using the PICOS paradigm, a systematic search was carried out in the PubMed and Cochrane databases to identify randomized controlled trials (RCTs) and prospective observational studies reporting survival data for CAD/CAM restorations. After selecting studies with a predefined set of selection criteria, data from included prospective clinical studies and RCTs were used for a systematic review aimed at a descriptive analysis of factors associated with failure of CAD-CAM restorations. Data from the included prospective clinical studies were used for meta-analysis, wherein 5-year and 10-year survival and success rates were estimated using Poisson regression models. The systematic review included data from 9 RCTs and 6 observational studies, which had a median follow-up of 36 months and 60 months, respectively. About 58 failures and 118 technical/ biological complications were noted in the included RCTs and 9 failures along with 58 technical/biological complications were noted in the prospective clinical studies. Poisson regression indicated an estimated 5-year and 10-year survival rates of 85.55-100 and 71-100, respectively. The estimated 5-year and 10-year success rates were 74.2-92.75 and 33.3-85.5, respectively. Several technical and biological complications contribute to failure of CAD/CAM restorations. However, CAD/CAM restorations with routine chairside materials might have clinically meaningful success rates in the long term. The results presented herein indicate that optimal strategies for mitigation of biological and technical complications may augment the success of CAD/CAM fabrications in restorative dentistry. Studies aimed at identification of such strategies are needed to further enhance the long-term success rates of CAD/CAM restorations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.