Abstract

Coiling temperature, finish rolling temperature and running speed of ZSAC1 strip during U-type cooling and number of valves which had been turned on were analyzed in order to find out the reason of low coiling temperature at tail of ZSAC1 strip in U-type cooling process. Results of research showed that running speed of strip and finish rolling temperature were main factors affecting accuracy of coiling temperature. Coiling temperature decreased with the increase of running speed of strip. Coiling temperature fluctuation would occur at the same part of strip when finish rolling temperature increased or decreased. Holding rolling speed and rolling temperature of strip stably can improve accuracy of coiling temperature during downstream U-type cooling.