Abstract

Aeration is the most energy intensive unit operation in municipal wastewater treatment. To improve oxygen transfer rate, fine-pore diffusers have been wildly applied in aeration practice. However, during operation, this type of diffuser suffers from fouling and scaling problems, which cause a rapid decline in aeration performance and significant increase in energy consumption. Diffusers must be cleaned periodically to reduce energy costs. The cleaning frequency of diffusers is site-specific, and can be evaluated by oxygen transfer efficiency (OTE) measurements over time in operation. Off-gas testing is the only technique that directly measures oxygen transfer efficiency in real-time. This paper presents a time-series of off-gas measurements which demonstrate the value of implementing energy-conservation practices. Our results include the real-time prediction of plant load and alpha factors from off-gas testing, as well as the quantification of the increased energy costs caused by fouling. Our off-gas analyzer can be used to develop an aeration efficiency monitoring protocols, and an aeration feedback control system for blowers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.