Abstract

This paper presents a real-time control strategy for nitrogen removal via nitrite in a continuous flow SHARON reactor using on-line available and industrially feasible sensors (pH and ORP). The developed control strategy optimizes the length of aerobic and anoxic phases as well as the external carbon source addition. This strategy, implemented in a laboratory-scale SHARON reactor fed with synthetic wastewater and real dewatering sludge supernatant, was able to cope with step variations in influent flow rate and ammonium concentration. The main advantages of this control strategy over the traditional operation mode with fixed carbon source dosification and fixed length cycle operation were: better effluent quality (ammonia concentration decreased from 12 to 2mgNH4–NL−1 and nitrogen removal efficiency raised from 95% to 98%) as result of the shorter cycle length: 2.9h versus 4.0h, and savings in external carbon addition: 1332mgCODd−1 versus 2100mgCODd−1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.