Abstract

IntroductionVentolin Nebules® (reference product; GlaxoSmithKline) was the first licensed nebulizer solution containing the rapid-onset, short-acting β2-agonist salbutamol. Salbutamol Steri-Neb™ (comparator; Teva Pharmaceuticals, Inc.) has the same chemical composition as the reference product. This study evaluated whether the effectiveness of the comparator is non-inferior to the reference product alongside concomitant medications during real-life clinical management of COPD exacerbations. Safety in terms of adverse events (AEs) was also examined.MethodsThis matched (1:1) historical cohort study evaluated data from 2 UK primary care databases on patients prescribed the salbutamol comparator or reference. The study included a 1-year baseline period, starting 1 year before the index prescription date, and 1-year outcome period. Cohorts were matched for baseline COPD respiratory medications. The primary outcome was analysis of non-inferiority for the comparator versus reference product for the rate of moderate and severe COPD exacerbations. Non-inferiority was satisfied if the 95% confidence interval (CI) upper limit for mean differences in proportions between treatments was <15%. Secondary outcomes were examined through rate ratios (RR) of severe exacerbations and AEs.ResultsAfter matching, 1191 patients were included in each cohort. Adjusted upper 95% CI for the difference in proportion of patients experiencing moderate or severe exacerbations between comparator and reference groups was 0.032 (3.2%), demonstrating non-inferiority. No significant differences were observed in rates of moderate and severe exacerbations (RR: 1.00; 95% CI: 0.91, 1.10), severe exacerbations (RR: 0.76; 95% CI: 0.49, 1.17), or AEs (RR: 0.98; 95% CI: 0.78, 1.22) after adjusting for baseline confounders. No significant differences across cohorts were observed for rates of any AE or death.ConclusionThis matched cohort study of real-life management of COPD patients supports the salbutamol comparator as non-inferior to the reference product, providing an effective treatment alternative for COPD exacerbations. Comparator and reference safety profiles were similar.

Highlights

  • Ventolin Nebules® was the first licensed nebulizer solution containing the rapid-onset, short-acting β2-agonist salbutamol

  • This study was approved by the Anonymised Data Ethics Protocols and Transparency (ADEPT) Committee —the independent scientific advisory committee for the OPCRD, commissioned by the Respiratory Effectiveness Group—and the Independent Scientific Advisory Committee (ISAC) for the CPRD

  • Chronic obstructive pulmonary disease (COPD) is a common, progressive, inflammatory disease characterized by persistent airflow limitation [1]

Read more

Summary

Introduction

Ventolin Nebules® (reference product; GlaxoSmithKline) was the first licensed nebulizer solution containing the rapid-onset, short-acting β2-agonist salbutamol. Salbutamol SteriNebTM (comparator; Teva Pharmaceuticals, Inc.) has the same chemical composition as the reference product. This study evaluated whether the effectiveness of the comparator is noninferior to the reference product alongside concomitant medications during real-life clinical management of COPD exacerbations. Safety in terms of adverse events (AEs) was examined

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call