Abstract

To evaluate the real-world effectiveness of automated insulin delivery (AID) systems in patients with type 1 diabetes (T1D). PubMed, Embase, the Cochrane Library, and ClinicalTrials.gov were searched for studies published up until 2 March 2024. We included pragmatic randomized controlled trials (RCTs), cohort studies, and before-after studies that compared AID systems with conventional insulin therapy in real-world settings and reported continuous glucose monitoring outcomes. Percent time in range (TIR; 3.9-10 mmol/L), time below range (TBR; <3.9 mmol/L), time above range (TAR; >10 mmol/L), and glycated haemoglobin (HbA1c) level were extracted. Data were summarized as mean differences (MDs) with 95% confidence interval. A total of 23 before-after studies (101 704 participants) were included in the meta-analysis. AID systems were associated with an increased percentage of TIR (11.61%, 10.47 to 12.76; p < 0.001). The favourable effect of AID systems was consistently observed when used continuously for 6 (11.76%) or 12 months (11.33%), and in both children (12.16%) and adults (11.04%). AID systems also showed favourable effects on TBR (-0.53%, -0.63 to -0.42), TAR (-9.65%, -10.63 to -8.67) and HbA1c level (-0.42%, -0.47 to -0.37) when compared with previous treatments. Similar improvements in glycaemic parameters were observed in real-world settings in RCTs using AID systems in T1D. AID systems benefit both children and adults by increasing TIR for both short- and long-term interventions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call