A real-time processing system for the two-color CO2 laser interferometer on the JT-60SA has been developed for density feedback control. The system has a novel feature that can detect fringe jumps due to off-normal events, such as loss detection due to displacement of the beam axis and changes in the laser wavelengths. Because a phase change due to the JT-60SA plasma is smaller than π/2, corresponding to the line-integral electron density NL of ∼6×1019 m-2 in a short interval of 500ns, the threshold of the fringe jump detection is decided to be π/2. Hence, off-normal events can be detected from a fringe jump, leading to the abort of the real-time feedback control. In the density feedback control of the JT-60SA plasma, the system is employed as a density monitor, with NL being successfully controlled at 16.8% ± 6.6% lower than the reference.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.