Abstract

BackgroundRapidly changing excitability states in an oscillating neuronal network can explain response variability to external stimulation, but if repetitive stimulation of always the same high- or low-excitability state results in long-term plasticity of opposite direction has never been explored in vivo. Objective/hypothesisDifferent phases of the endogenous sensorimotor μ-rhythm represent different states of corticospinal excitability, and repetitive transcranial magnetic stimulation (rTMS) of always the same high- vs. low-excitability state results in long-term plasticity of different direction. MethodsState-dependent electroencephalography-triggered transcranial magnetic stimulation (EEG-TMS) was applied to target the EEG negative vs. positive peak of the sensorimotor μ-rhythm in healthy subjects using a millisecond resolution real-time digital signal processing system. Corticospinal excitability was indexed by motor evoked potential amplitude in a hand muscle. ResultsEEG negative vs. positive peak of the endogenous sensorimotor μ-rhythm represent high- vs. low-excitability states of corticospinal neurons. More importantly, otherwise identical rTMS (200 triple-pulses at 100 Hz burst frequency and ∼1 Hz repetition rate), triggered consistently at this high-excitability vs. low-excitability state, leads to long-term potentiation (LTP)-like vs. no change in corticospinal excitability. ConclusionsFindings raise the intriguing possibility that real-time information of instantaneous brain state can be utilized to control efficacy of plasticity induction in humans.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call