Abstract

Sarcomere length of a cardiomyocyte is an important control parameter for physiology studies on a single cell level; for instance, its accurate determination in real time is essential for performing single cardiomyocyte contraction experiments. The aim of this work is to develop an efficient and accurate method for estimating a mean sarcomere length of a contracting cardiomyocyte using microscopy images as an input. The novelty in developed method lies in 1) using unbiased measure of similarities to eliminate systematic errors from conventional autocorrelation function (ACF)-based methods when applied to region of interest of an image, 2) using a semianalytical, seminumerical approach for evaluating the similarity measure to take into account spatial dependence of neighboring image pixels, and 3) using a detrend algorithm to extract the sarcomere striation pattern content from the microscopy images. The developed sarcomere length estimation procedure has superior computational efficiency and estimation accuracy compared with the conventional ACF and spectral analysis-based methods using fast Fourier transform. As shown by analyzing synthetic images with the known periodicity, the estimates obtained by the developed method are more accurate at the subpixel level than ones obtained using ACF analysis. When applied in practice on rat cardiomyocytes, our method was found to be robust to the choice of the region of interest that may 1) include projections of carbon fibers and nucleus, 2) have uneven background, and 3) be slightly disoriented with respect to average direction of sarcomere striation pattern. The developed method is implemented in open-source software.

Highlights

  • AS AN EXPERIMENTAL MODEL, isolated cardiomyocytes provide unique opportunities to study electrophysiology, mechanics, and bioenergetics

  • 2) The method of current work is applied to microscopy images for determining the mean sarcomere length of a contracting cardiomyocyte

  • We describe the corresponding procedure, analyze sensitivity of the method to different uncertainties that are inherent to the corresponding experimental conditions, and compare the dynamics of the mean sarcomere length time evolutions obtained from different methods: the method of current work and two methods based on discrete autocorrelation function (ACF) and Fourier spectrum analysis, respectively

Read more

Summary

Introduction

AS AN EXPERIMENTAL MODEL, isolated cardiomyocytes provide unique opportunities to study electrophysiology, mechanics, and bioenergetics. We assume that the captured data are in the form of microscopy images acquired with a high-speed camera This is a practical simplification as transmission images with sarcomere length information contain carbon fiber positional information that is needed for mechanical loading protocols. This information would not be readily available when using, for instance, laserlight diffraction-based techniques [7, 9, 11]. There are several requirements for the method of sarcomere length determination to make it useful in real-time control of cardiomyocyte contraction It must be accurate at subpixel resolution to allow the usage of faster cameras that have smaller resolution parameters. The mean sarcomere length is defined as the spatial period of this pattern

Objectives
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.