Abstract

Application of real time control systems within sewer networks is one of different possible measures taken against the problems with storm water runoff and combined sewer overflows (CSO) in urbanized areas. Practical investigations concerning the effect of this alternative way to reduce CSO have been made during four years in the sewer network of the community Ense-Bremen (near Dortmund). An implemented simple control strategy manages the flow and storage events aiming at an even degree of storage capacity at any detention tank and at any time. The comparison with model calculations, reveals that there are differences between both results especially those concerning the basin out-flows. These differences are mainly caused by the constraints of practical operation. Therefore it is necessary to develop control strategies considering these facts within its practical course.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.