Abstract

Purpose In spite of the vehicle, magnetic field interference can be reduced by some measures and techniques in ammunition design and manufacturing stage, the corruption of the vehicle magnetic field can still reach hundreds to thousands of nanoteslas. Besides, the magnetic field that the ferromagnetic materials generate in response to the strong magnetic field in the vicinity of the body. So, a real-time and accurate vehicle magnetic field calibration method is needed to improve the real-time measurement accuracy of the geomagnetic field for spinning projectiles. Design/methodology/approach Unlike the past two-step calibration method, the algorithm uses a linear model to calibrate the magnetic measurement error in real-time. In the method, the elliptical model of magnetometer measurement is established to convert the coefficients of hard and soft iron errors into the parameters of the elliptic equation. Then, the parameters are estimated by recursive least square estimator in real-time. Finally, the initial conditions for the estimator are established using prior knowledge method or static calibration method. Findings Studies show the proposed algorithm has remarkable estimation accuracy and robustness and it realizes calibration the magnetic measurement error in real-time. A turntable experiments indicate that the post-calibration residuals approximate the measurement noise of the magnetometer and the roll accuracy is better than 1°. The algorithm is restricted to biaxial magnetometers’ calibration in real-time as expressed in this paper. It, however, should be possible to broaden this method’s applicability to triaxial magnetometers' calibration in real-time. Originality/value Unlike the past two-step calibration method, the algorithm uses a linear model to calibrate the magnetic measurement error in real-time and the calculation is small. Besides, it does not take up storage space. The proposed algorithm has remarkable estimation accuracy and robustness and it realizes calibration the magnetic measurement error in real time. The algorithm is restricted to biaxial magnetometers’ calibration in real-time as expressed in this paper. It, however, should be possible to broaden this method’s applicability to triaxial magnetometers’ calibration in real-time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.