Abstract The main advantages of using niobium in reactor dosimetry are briefly summarized. Some experimental aspects and complications of niobium dosimetry are discussed. Special techniques can be applied to overcome most of these problems. Particular concern has to be given to the detector calibration for the X-ray measurements. The main problem however, embrittlement of pure niobium under intense neutron irradiation, is still not solved. For this purpose a new type of material (Al-10%Nb alloy) was prepared. Although testing of this material is still ongoing, preliminary results are promising. This material moreover does not necessarily require applying special techniques for the X-ray measurements. Finally it is explained that niobium is a suitable material for the determination of thermal and epithermal fluences in high flux environments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.