Abstract
This paper investigates the issues of reactive power must-run capacity in power system operations, hence in electricity markets. A must-run index-based method is proposed in the paper to measure the market power held by reactive power suppliers. The Nordic 32-bus system and the IEEE 118-bus system are used to test the proposed method. The market power holders of reactive power found using the proposed method are in accord with that found in the realistic Nordic system operation and in the existing analysis of IEEE 118-bus system. The paper identifies through must-run indices possible conditions that could lead to market power in the case of applying a bid structure within a market framework. Furthermore, market structure drawbacks can cause the appearance of market power even in a topologically ideal system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.