Abstract

Fetal vibroacoustic stimulation in fetuses with suspicious or ominous fetal heart rate traces in labour was followed by acid-base balance determination on fetal scalp blood within 30 min of the test. The mean fetal scalp blood pH values were significantly higher in fetuses that showed reactive responses with fetal heart rate acceleration compared with those who had no response or responded with a deceleration to the vibroacoustic stimulation (pH 7.30 and 7.22 respectively). However, acidotic scalp blood pH values (7.16 and 7.18) were found in two fetuses which had shown reactive responses both to vibroacoustic stimulation and pain stimuli with scalp blood sampling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.