Abstract

Reactive airway dysfunction syndrome, a type of occupational asthma without a latency period, is induced by irritating vapour, fumes or smoke. The present report is the first to describe a case of reactive airway dysfunction syndrome caused by acute exposure to dishwater detergent containing sodium metasilicate and sodium dichloroisocyanurate. The diagnosis was based on exposure data, clinical symptoms and signs, as well as respiratory function tests. A 43-year-old nonatopic male apprentice cook developed respiratory symptoms immediately after exposure to a cloud of detergent powder that was made airborne by vigorous shaking of the package. In spirometry, combined obstructive and restrictive ventilatory impairment developed, and the histamine challenge test revealed bronchial hyper-responsiveness. Even routine handling of a strongly caustic detergent, such as filling a dishwasher container, is not entirely risk free and should be performed with caution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.