Abstract

Lime is widely utilized as a sorbent in dry and semidry sulfur removal processes. In this study limestone was calcined at high temperature and lime was produced by water vapor steam treatment at low temperature. Experiments were performed at conditions that also cover those usually present in coal-fired power plants. The investigation of the reaction of lime with synthetic flue gas showed that the relative humidity of the gas has a major impact on the reactivity. Also the presence of oxygen and/or carbon dioxide does not show a significant influence on the sulfur dioxide removal reaction though some intermediate formation of calcium carbonate cannot be excluded. Mainly calcium sulfite hemihydrate was found to be the reaction product, but some calcium sulfate hemihydrate was also formed when oxygen was present. Four regions with different prevailing reaction mechanisms can be defined: In the beginning the formation of a monolayer is mainly determined by the SO2 concentration and to some smaller extent als...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.