Abstract

ABSTRACT: This work begins by defining rational water use, and then discusses important factors that most strongly influence it. A general model is then developed to enable factories to quantify the ratio of rational industrial water reuse based on the least cost method. The model is established to minimize the cost of water with reference to gross water use and three subsystems ‐ the intake, reuse, and discharge of industrial water. Discharge cost is determined using data from a 1997 survey of 38 factories, and reuse costs are ranked and expressed by a step function. The model is verified using data from a typical semiconductor factory in northern Taiwan's Hsinchu Science Based Industrial Park, whose effective rational water reuse ratio is about 38 percent. A sensitivity analysis shows that improving water reuse technology is the most important factor in determining the rational water reuse ratio, and the price of water is the second most important. When water costs over NT$30 (New Taiwan Dollar, US$1 = NT$34) per cubic meter, increasing reuse becomes significant. The model provides a step towards the scientific management of industrial water.