Abstract

AbstractThe fault tolerant control (FTC) problem based on rational entropy performance criteria is researched for fuzzy descriptor stochastic distribution networked control (SDNC) systems with packet dropout. The independent Bernoulli distribution is employed to describe the packet dropout in the feedback channel. The static model and the dynamic model of descriptor SDNC systems are built up by the rational square‐root fuzzy logic model (FLM) and the T‐S fuzzy model, respectively. When the given output probability density function (PDF) is not known, the minimization of output randomness becomes an important control target. First, the unknown fault is estimated by developing the fuzzy fault estimation observer. Then, the fault tolerant controller with the fault compensation is designed so that the output of the descriptor SDNC system remains with the minimum uncertainty after the fault occurs. A simulation example is supplied to prove the proposed scheme.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.