Abstract

Estimating the rate of glaucomatous visual field change provides practical assessment of disease progression and has implications for management decisions. To assess the rates of visual field change in patients receiving treatment for glaucoma compared with healthy individuals over an extensive follow-up period and to quantify the impact of important covariates for these rates. This prospective longitudinal cohort study was conducted in a hospital-based setting from January 1991 to February 2020. The study included 40 patients receiving treatment for open-angle glaucoma and 29 healthy participants. One eye of each participant was randomly selected as the study eye. Patients with glaucoma and healthy participants received testing with standard automated perimetry every 6 months. Individual rates of mean sensitivity change were computed using ordinary least-squares regression analysis, and linear mixed-effects modeling was used to estimate the mean rates of mean sensitivity change in the 2 groups and the impact of baseline mean sensitivity, baseline age, and follow-up intraocular pressure for rate estimates. Rate of mean sensitivity change in patients with glaucoma and healthy participants. A total of 40 patients with glaucoma (median age, 53.07 years [IQR, 48.34-57.97 years]; 21 men [52%]) and 29 healthy participants (median age, 48.80 years [IQR, 40.40-59.07 years], 17 women [59%]) were followed up for a median of 25.65 years (IQR, 22.49-27.02 years) and 19.56 years (IQR, 16.19-26.21 years), respectively. Most participants (65 individuals [94%]) self-identified as White, with the exception of 2 patients with glaucoma (1 self-identified as Black and 1 as South Asian) and 2 healthy participants (both self-identified as South Asian). The mean follow-up intraocular pressure of patients with glaucoma (median, 15.83 mm Hg [IQR, 13.05-17.33 mm Hg]) was similar to that of healthy participants (median, 14.94 mm Hg [IQR, 13.28-16.01 mm Hg]; P = .25). In an ordinary least-squares regression analysis, 31 patients (78%) with glaucoma had rates of mean sensitivity change within the range of healthy participants (ie, between -0.20 dB/y and 0.15 dB/y). Linear mixed-effects modeling revealed that the mean (SE) rate of mean sensitivity change in healthy participants was 0.003 (0.033) dB/y (95% CI, -0.062 to 0.068; P = .93). In comparison, patients with glaucoma had a mean (SE) rate of mean sensitivity change that was -0.032 (0.052) dB/y faster, but this difference was not statistically significant (95% CI, -0.134 to 0.070; P = .53). Among covariates, only baseline mean sensitivity was associated with the rate of mean sensitivity change (mean [SE], 0.021 [0.010] dB/y/dB; 95% CI, 0.002-0.041; P = .03). The results of this cohort study suggest that over a median follow-up of more than 25 years, the rate of visual field change in patients receiving treatment for glaucoma was comparable to that of healthy individuals. These findings could guide practitioners in making management decisions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.