Abstract
Magnetic resonance imaging (MRI) is increasingly being integrated into the radiation oncology workflow, due to its improved soft tissue contrast without additional exposure to ionising radiation. A review of MRI utilisation according to evidence based departmental guidelines was performed. Guideline utilisation rates were calculated to be 50% (true utilisation rate was 46%) of all new cancer patients treated with adjuvant or curative intent, excluding simple skin and breast cancer patients. Guideline utilisation rates were highest in the lower gastrointestinal and gynaecological subsites, with the lowest being in the upper gastrointestinal and thorax subsites. Head and neck (38% vs 45%) and CNS (46% vs 67%) cancers had the largest discrepancy between true and guideline utilisation rates due to unnamed reasons and non-contemporaneous diagnostic imaging respectively. This report outlines approximate MRI utilisation rates in a tertiary radiation oncology service and may help guide planning for future departments contemplating installation of an MRI simulator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.