Abstract

BackgroundThe impact of suture type on tensile strength, re-rupture rates and infection risk in Achilles tendon rupture repair is not been well established. The aim of this review is to evaluate existing literature on the associated risk of postoperative infection with absorbable and non-absorbable suture materials in Achilles tendon rupture repair. MethodsA systematic review of search databases PubMed; Google Scholar; and OVID Medline was made to identify studies related to complications associated with Achilles tendon rupture repair. PRISMA guidelines were utilised for this review. Meta-analysis was used to compare rupture rates and infections following rupture repair. Results12 studies with a total of 460 patients, 230 in both nonabsorbable and absorbable suture groups were included for analysis. Risk of wound complications was significantly higher in patients with non-absorbable sutures (p < 0.001). ConclusionNonabsorbable braided sutures is associated with the highest risk of postoperative wound complications following Achilles tendon rupture repair.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.