Abstract

Anterior cruciate ligament (ACL) reconstruction, using an ipsilateral hamstring graft, may necessitate an alternative graft source if the obtained graft is insufficient with regards to length or diameter. The study aims to determine the rate of insufficient ipsilateral hamstring graft harvesting in primary ACL reconstruction. Retrospective review of 50 consecutive primary ACL reconstructions performed by a single surgeon in the United Kingdom. In 3 of 50 cases, there was insufficient ipsilateral hamstring graft harvesting and a contralateral hamstring graft was used. In two cases, this was due to premature division of the ipsilateral hamstring tendons (3/100 harvested tendons). In one case, an adequate length of semitendinosus was obtained, but its central portion was too thin. Retrospective review of preoperative magnetic resonance imaging identified the thin part of the tendon in the latter case. Insufficient ipsilateral hamstring graft harvesting is a recognized, yet unusual intraoperative complication in primary ACL reconstruction. Presurgical planning as to how to manage such complications is essential.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.