Abstract

The present study is concerned with the removal rate of Copper ions Cu++ from wastewater by cementation of copper from copper sulfate solution on a horizontal steel sheet placed at the bottom of a square stirred tank reactor and fitted with square steel turbulence promoters. The variables studied were solution concentration, rotation speed, impeller geometry, promoter diameter and distance between promoters. The rate of mass transfer was found to increase with the rotational speed and decreased with the increase of distance between promoters. The data were correlated to develop the relationship Sh α Re x

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.