Abstract
AbstractThe application of recycled aggregate is crucial for waste concrete recycling, while the loading rate significantly influences the fracture behavior of recycled aggregate concrete. Herein, we investigate the effect of loading rate on the flexural and fracture behaviors of recycled aggregate concrete, along with associated acoustic emission characteristics. Results show that the flexural strength and energy absorption capacity maximum increase by 15.18% and 38.39%, respectively, as the loading rate rises. As the loading rate increases from 0.05 to 1 mm/min, peak frequency is primarily clustered in 0 ~ 75 kHz and 75 ~ 225 kHz and tends to be dense, while the b value decreases by 19.28%, 23.30%, and 30.17%, respectively. Additionally, the proportion of shear failure also decreases, which relates to the high energy release rate. Further, the multifractal spectrum α − f(α) resembles a quadratic distribution, with both multifractal intensity ∆f and spectrum width ∆α showing a downward trend as the loading rate rises.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Fatigue & Fracture of Engineering Materials & Structures
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.