Abstract
The rat femoral vein has become a standard model for microvascular anastomosis practice as well as for research investigations into various manipulative influences upon venous patency. Although vein grafts to the rat artery are the focus of many experimental studies, few reports have investigated vein-to-vein grafts. This study examines the short-term patency (1-3 days) of vein grafts interpositioned to the rat femoral vein. Several factors are studied for their ability to alter the patency rate. The results indicate that patency is difficult to achieve following the creation of a second serial anastomosis (construction of a vein-to-vein graft). Systemic heparin consistently improves patency rates, and trends toward increased patency are seen for reduction in longitudinal tension of the repaired vessel. It is also implied that a deeper understanding of venous hemodynamics and thrombotic events may lead to improved methodologies in the clinical applications of microvenous repairs. These results indicate that rat vein-to-vein grafts may provide a challenging microvascular training model, while introducing the novice microsurgeon to some of the complicating factors encountered with microvascular grafting.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.