Abstract

A rapid whole blood test has been developed for circulating antibodies to human immunodeficiency virus type 1 (HIV-1), based on agglutination of autologous red blood cells. Evaluation of the test revealed that 100% of seropositive HIV-1 patients (both asymptomatic and AIDS cases) were detected ( n = 94) with a specificity of 99.5% in healthy blood donors ( n = 596). The assay uses an Fab fragment of a monoclonal antibody specifically directed against glycophorin (a transmembrane glycoprotein present on the surface of human red blood cells). This anti-red blood cell Fab is conjugated via the inter-heavy chain cysteines to a synthetic peptide corresponding to the immunodominant epitope of the HIV-1 viral coat protein gp41 (579–613). Addition of this reagent to 10 μl of whole blood results in the Fab-peptide conjugate coating the red blood cells with peptide. In the presence of circulating antibodies to the HIV-1 peptide, red cell agglutination occurs within 2 min. The sensitivity and specificity of this reagent indicate that it is appropriate for use as a rapid diagnostic test for HIV-1 seropositivity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.