Abstract

Vacuum extraction is a common technique of assisted vaginal delivery. Traditionally, it has been recommended that the pressure is increased slowly in a stepwise procedure; some have advocated rapid increases in pressure. To assess the efficacy and safety of rapid versus stepwise negative pressure application for assisted vaginal delivery by vacuum extraction. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (4 April 2012). Randomized controlled trials and quasi-randomized controlled trials of rapid (within two minutes) versus stepwise (as defined by trialists) increases in negative pressure application for vacuum extraction assisted vaginal delivery. Two review authors independently assessed trials for inclusion and trial quality. The same two review authors extracted data. We entered data into Review Manager software and checked for accuracy. Data extraction and 'Risk of bias' assessment of the contact person's own study were also carried out by three independent assessors who were not involved in the new study. We included two trials involving 754 participants.One new trial of 660 participants showed the same success rate of vacuum procedure of 98.2% by both methods (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.98 to 1.02).The two included trials showed significant reductions in the time between applying the vacuum cup and delivery, (one trial (74 women): mean difference (MD) -6.10 minutes, 95% CI -8.83 to -3.37 and the other trial (660 women): with median difference -4.4 minutes, 95% CI -4.8 to -4.0). The two included trials showed no significant difference in detachment rate (RR 0.85, 95% CI 0.38 to 1.86, 2 studies, 754 women), no significant difference in Apgar score below seven at one minute (RR 1.04, 95% CI 0.51 to 2.09) and five minutes (RR 1.00, 95% CI 0.29 to 3.42), no significant differences in scalp abrasions or lacerations, cephalhematoma, subgaleal hemorrhage andhyperbilirubinemia. There were no significant differences between the two methods in all secondary outcomes. The rapid negative pressure application for vacuum assisted vaginal birth reduces duration of the procedure whilst there is no evidence of differences in maternal and neonatal outcomes. Rapid method of negative application should be recommended for vacuum extraction assisted vaginal delivery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.