Abstract

To remove brass plating on fine saw wire, line-shaped magnetron plasma source has been newly developed. New type of multiple plasma sources has been developed by applying to multiple-triangle-type electrodes. The stripping effects were successfully established by using high density magnetron source with 20mm gap in an axially applied magnetic field. From the EDS analysis results of wire surface after plasma stripping during 30sec, it is clearly shown that Zn was removed after 10sec stripping and Cu after 30sec. (Fe:38.5%?97.7%, Cu:39.3%?2.43%, Zn:22.2%? 0.03%)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.