We report on the improvement of conditions for the rapid start of oscillations in magnetrons by increasing the amplitude of the operating wave that is responsible for the capture of electrons into spokes. This amplitude increase is achieved by using a hollow cathode with longitudinal strips removed, thereby making the cathode transparent to the wave electric field with azimuthal polarization. In addition, an optimal choice of the number and position of cathode strips provide favorable prebunching of the electron flow over the cathode for fast excitation of the operating mode. Particle-in-cell simulations of the A6 magnetron demonstrate these advantages of this novel cathode.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.