Diabetes mellitus is a chronic disease with high and growing prevalence worldwide. Therefore, the development of fast and efficient methods for the QC of antidiabetic drugs is of fundamental importance. Two ultra-fast methods, using a conventional (C18 100 × 2.1 mm, 5 μm fully porous particle) column or a fused-core (C18 100 × 2.1 mm, 2.7 μm fused-core particle) column, were developed for the simultaneous determination of four antidiabetic drugs (chlorpropamide, glibenclamide, gliclazide, and glimepiride). The developed methods were compared in terms of efficiency, speed of analysis, resolution, and peak symmetry. Both methods were validated with respect to selectivity, system suitability, linearity, precision, accuracy, LOD, LOQ, and robustness, using glibenclamide as model. Conventional and fused-core methods were shown to be appropriate for the determination of glibenclamide in tablets; however, the fused-core column presented higher efficiency, detectability, and resolution. Also, it enabled faster analysis, with separation of the four drugs in less than 1 min.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.