A rapid quantitative microenzyme-linked immunosorbent assay for the detection of immunoglobulin G antibodies to tetanus toxoid is described. The assay is performed in 2.5 h and detects antibody levels of between 0.1 and 6 U/ml. Quantitation of the antibody concentration is unique in that multiple serum dilutions are tested on a single patient, the results are plotted as an antibody dilution curve, and the area under the curve is integrated for a final concentration. Tests for immune status on sera from 77 individuals demonstrated tetanus antibody concentrations of greater than or equal to 0.1 U/ml in 92% of a pediatric group and 62% of an adult group. The microenzyme-linked immunosorbent assay procedure is reproducible and is useful for the determination of immune status and immunization response.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.