Abstract
FROC and AFROC analyses are useful in medical imaging to characterize detection performance for the case of multiple lesions. We had previously developed<sup>1</sup> ideal FROC and AFROC observers. Their performance is ideal in that they maximize the area or any partial area under the FROC or AFROC curve. Such observers could be useful in imaging system optimization or in assessing human observer efficiency. However, the performance evaluation of these ideal observers is impractically computationally complex. We propose 3 reasonable assumptions under which the ideal observers reduce approximately to a particular form of a scan-statistic observer. Performance for the "scan-statistic-reduced ideal observer" can be evaluated far more rapidly albeit with slight error than that of the originally proposed ideal observer. Through simulations, we confirm the accuracy of our approximate ideal observers. We also compare the performance of our approximate ideal observer with that of a conventional scan-statistic observer and show that the performance of our approximate ideal observer is significantly greater.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.