Abstract
A rapid non-destructive experimental method was used to assess the permeability of different brands of commercial corrugated fibercement roofing sheets. In comparison to standardized methods that take up to 24 h to complete, the proposed method allowed for air and water permeability analyses in 5 and 30 min, respectively. The air permeability coefficient of tested sheets ranged from 1.4 × 10-16 to 1.6 × 10-14 m2. The water permeability coefficient was one order of magnitude lower (2.8×10-17 to 6.6×10-16 m2), confirming the interference of hydrophobic/waterproofing components in the formulation. There was no direct relationship between sheet thickness and air or water permeation resistance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.