Abstract

A rapid non-destructive experimental method was used to assess the permeability of different brands of commercial corrugated fibercement roofing sheets. In comparison to standardized methods that take up to 24 h to complete, the proposed method allowed for air and water permeability analyses in 5 and 30 min, respectively. The air permeability coefficient of tested sheets ranged from 1.4 × 10-16 to 1.6 × 10-14 m2. The water permeability coefficient was one order of magnitude lower (2.8×10-17 to 6.6×10-16 m2), confirming the interference of hydrophobic/waterproofing components in the formulation. There was no direct relationship between sheet thickness and air or water permeation resistance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.