Abstract

A confirmatory method was developed to allow for the analysis of eleven nitroimidazoles and also chloramphenicol in milk and honey samples. These compounds are classified as A6 compounds in Annex IV of Council Regulation 2377/90 (European Commission 1990) and therefore prohibited for use in animal husbandry. Milk samples were extracted by acetonitrile with the addition of NaCl; honey samples were first dissolved in water before a similar extraction. Honey extracts underwent a hexane wash to remove impurities. Both milk and honey extracts were evaporated to dryness and reconstituted in initial mobile phase. These were then injected onto a liquid chromatography-tandem mass spectrometry (LC-MS/MS) system and analysed in less than 9 min. The MS/MS was operated in multiple reaction monitoring (MRM) mode with positive and negative electrospray ionization. The method was validated in accordance with Commission Decision 2002/657/EC and is capable of analysing metronidazole, dimetridazole, ronidazole, ipronidazole and there hydroxy metabolites hydroxymetronidazole, 2-hydroxymethyl-1-methyl-5-nitroimidazole, and hydroxyipronidazole. The method can also analyse for carnidazole, ornidazole, ternidazole, tinidazole, and chloramphenicol. A recommended level of 3 µg l−1/µg kg−1 for methods for metronidazole, dimetridazole, and ronidazole has been recommended by the Community Reference Laboratory (CRL) responsible for this substance group, and this method can easily detect all nitroimidazoles at this level. A minimum required performance level of 0.3 µg l−1/µg kg−1 is in place for chloramphenicol which the method can also easily detect. For nitroimidazoles, the decision limits (CCα) and detection capabilities (CCβ) ranged from 0.41 to 1.55 µg l−1 and from 0.70 to 2.64 µg l−1, respectively, in milk; and from 0.38 to 1.16 µg kg−1 and from 0.66 to 1.98 µg kg−1, respectively, in honey. For chloramphenicol, the values are 0.07 and 0.11 µg l−1 in milk and 0.08 and 0.13 µg kg−1 in honey. Validation criteria of accuracy, precision, repeatability, and reproducibility along with measurement uncertainty were calculated for all analytes in both matrices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.